Integración de sistemas fotovoltaicos en edificios de oficinas en bajas latitudes: estudio del balance energético aplicado a Brasil
dc.contributor | Vega Sánchez, Sergio ; orcid:0000-0002-4180-5089 | |
dc.contributor | Caamaño Martín, Estefanía ; orcid:0000-0001-5099-7150 | |
dc.coverage | east=-51.92527999999999; north=-14.235004; name=Brasil | |
dc.creator | Cronemberger Ribeiro Silva, Joara | |
dc.date.accessioned | 2024-07-17T06:56:21Z | |
dc.date.available | 2024-07-17T06:56:21Z | |
dc.date.issued | 2015-12 | |
dc.description | La hipótesis que inspiró esta tesis sostiene que la integración de componentes fotovoltaicos en los cerramientos opacos y sombreamientos de huecos acristalados de edificios de oficinas en sitios ubicados en bajas latitudes, tomando como el ejemplo el caso concreto de Brasil, podría incrementar su eficiencia energética. Esta posibilidad se basa en el bloqueo de una parte significativa de la irradiación solar incidente en estos edificios, reduciendo así las cargas térmicas para la climatización y a la vez transformándola en energía eléctrica, a tal punto que se amortizan los costes de inversión en plazos aceptables a través de los ahorros en la demanda de energía. Para verificar esta hipótesis de partida se ha propuesto como objetivo general analizar la integración de elementos fotovoltaicos en cubiertas, muros opacos y sombreamiento de huecos acristalados desde la óptica del balance energético térmico y eléctrico. Inicialmente se presenta y analiza el estado del arte en los temas estudiados y la metodología de investigación, de carácter teórico basada en cálculos y simulaciones. A partir de un modelo tipo de edificio de oficinas situado en Brasil, se definen cuatro casos de estudio y una serie de parámetros, los cuales se analizan para siete latitudes ubicadas entre -1,4° y -30°, separadas las unas de las otras por aproximadamente 5°. Se presentan y discuten los resultados de más de 500 simulaciones para los siguientes conceptos: - recurso solar, desde la perspectiva de la disponibilidad de irradiación solar en distintas superficies de captación apropiadas para la integración de sistemas solares fotovoltaicos en edificaciones en bajas latitudes; - análisis de sombras, con objetivo de identificar los ángulos de sombras vertical (AVS) para protección de huecos acristalados en edificios de oficinas; - balance energético térmico, para identificar el efecto térmico del apantallamiento provocado por componentes fotovoltaicos en cubiertas, muros opacos y parasoles en ventanas en las cargas de refrigeración y consecuentemente en las demandas de energía eléctrica; - balance energético eléctrico, contrastando los resultados del balance térmico con la energía potencialmente generada en las envolventes arquitectónicas bajo estudio; - análisis económico, basado en un escenario de precios de la tecnología fotovoltaica de un mercado maduro y en la política de inyección a la red marcada por la actual normativa brasileña. Se han verificado los potenciales de ahorro económico que los sistemas activos fotovoltaicos podrían aportar, y asimismo se calculan diversos indicadores de rentabilidad financiera. En suma, esta investigación ha permitido extraer conclusiones que contribuyen al avance de la investigación y entender las condiciones que propician la viabilidad de la aplicación de componentes fotovoltaicas en las envolventes de edificios en Brasil, y hasta un cierto punto en otros países en latitudes equivalentes. ABSTRACT The hypothesis that inspired this thesis sustains that integration of photovoltaic components in the opaque envelope and shading elements of office buildings placed at low-latitude countries, using the specific case of Brazil, could increase its energy efficiency. This is possible because those components block a significant part of the incident solar irradiation, reducing its heating effect on the building and transforming its energy into electricity in such a way that the extra investments needed can be paid back in acceptable periods given the electricity bill savings they produce. In order to check this hypothesis, the main goal was to analyze the thermal and electrical performance of photovoltaic components integrated into roofs, opaque façades and window shadings. The first step is an introduction and discussion of the state of the art in the studied subjects, as well as the chosen methodology (which is theoretical), based on calculations and simulations. Starting from an office building located in Brazil, four case studies and their parameters are defined, and then analyzed, for seven cities located between latitudes -1.4° and -30°, with an approximate distance of 5° separating each one. Results of more than 500 simulations are presented and discussed for the following concepts: - Solar resource, from the perspective of irradiation availability on different surfaces for the integration of photovoltaic systems in buildings located at low latitudes; - Shading analysis, in order to determine the vertical shading angles (VSA) for protection of the glazed surfaces on office buildings; - Thermal energy balance, to identify the screening effect caused by photovoltaic components on roofs, opaque façades and window shadings on the cooling loads, and hence electricity demands; - Electric energy balance, comparing thermal energy balance with the energy potentially generated using the active skin of the buildings; - Economic analysis, based on a mature-market scenario and the current net metering rules established by the Brazilian government, to identify the potential savings these photovoltaic systems could deliver, as well as several indicators related to the return on the investment. In short, this research has led to conclusions that contribute to the further development of knowledge in this area and understanding of the conditions that favor the application of photovoltaic components in the envelope of office buildings in Brazil and, to a certain extent, in other countries at similar latitudes. | |
dc.format | application/pdf | |
dc.format | application/pdf | |
dc.format | application/pdf | |
dc.format | application/pdf | |
dc.identifier.uri | https://biblioteca-juandevillanueva.coam.org/handle/123456789/1871 | |
dc.identifier.uri | https://oa.upm.es/39830/ | |
dc.language | spa | |
dc.language | spa | |
dc.language | spa | |
dc.language | spa | |
dc.publisher | E.T.S. Arquitectura (UPM) | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/10.20868/UPM.thesis.39830 | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/3.0/es/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Arquitectura | |
dc.title | Integración de sistemas fotovoltaicos en edificios de oficinas en bajas latitudes: estudio del balance energético aplicado a Brasil | |
dc.type | Tesis | |
dc.type | info:eu-repo/semantics/doctoralThesis | |
dc.type | PeerReviewed |